Product Description Large Capacity Air Cooled Scroll Chiller (Heat Pump OR Only Cooling) * Vtype heat exchanger, uniform airflow distribution and fully exchange heat. * Fan and motor: Large air flow, optimized blade design makes quiet operation. The fan motor is large torque and high efficiency...
ارسال درخواست
معرفی محصول

 

* Electric control box: Leading brand components are adopt- ed to ensure quality.The electric control box is designed on the front side to make installation fast and maintenance convenient.

* Water side heat exchanger: The newly design of spiral baffle shell and tube evaporator improves 10% heat exchanging efficiency.

KASSEL large capacity air ccooled scroll chiller adopts a modular design. Two basic modules and max.8 units can be combined. The unit can be widely used in various buildings, including hotels, hospitals, schools, factories, and office buildings, etc.

 

 

Maintenance of water-cooled chiller

During normal operation of water-cooled chillers, it is inevitable that dirt or other impurities will affect the cooling effect. Therefore, in order to extend the service life of the main unit and achieve a better cooling effect, regular maintenance and maintenance work should be done to ensure the quality of the chiller unit and improve production efficiency. The specific content is as follows:

1. Regularly check whether the voltage and current of the chiller are stable, and whether the compressor is running normally. When the chiller is working normally, the voltage is 380V and the current is within the range of 11A-15A.

2. Regularly check whether the chiller refrigerant leaks: refer to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature (winter, summer) temperature changes, the pressure display of the chiller is also different. When the chiller is working normally, the high pressure display is generally 11-17kg, and the low pressure display is normal within the range of 3-5kg.

3. Check whether the cooling water system of the chiller is normal, whether the cooling tower fan and sprinkler shaft are running well, and whether the water supply of the built-in water tank of the chiller is normal.

4. The system should be cleaned when the chiller is used for six months, and cleaned once a year. The main cleaning parts include: cooling water tower, radiator pipes and condenser parts to ensure better cooling effect.

5. When the chiller is not used for a long time, turn off the circuit switches of the water pump, compressor and the main power supply of the cooling water tower in time.

 